One-Stop Services

We don’t just sell hardware; we build complete ecosystems. From facility construction to software platforms, we handle it all.

AI data hall under construction, modules being craned into place
Site build and module delivery running together
Turnkey delivery

One accountable line, site to operation

01Site selection
02Planning & design
03Installation
04Commissioning
05Operation
0
Servers supportedscales from 100 upward
0%
Cooling cost cutagainst an air-cooled baseline
Tier III
Design grademeets the international data center tier standard

AIDC Strategy

Total Service

Complete liquid-cooled data center construction service, from site selection and planning to equipment installation and commissioning. Providing enterprise-grade infrastructure with high reliability and scalability.

Open PMDC container with IT racks fitted out in the factory
Factory-built module, integration-tested before it ships
Where the heat goes

87% captured by liquid, the rest by air

Direct-to-chip liquid87% Air side13%
Scale by adding identical, factory-tested blocks
0kWper identical, factory-tested unit

Prefabricated Modular Data Center

PMDC · AI-Ready Solution

Factory-built IT, power and cooling modules — integration-tested, then assembled and commissioned on site. A Tier III Ready reference design engineered for NVIDIA GB300 NVL72, delivered in up to half the time of conventional construction.

Liquid-cooled server rack with coolant hoses on the rack face
Direct-to-chip liquid cooling at the rack
Primary, CDU, secondary

Coolant to every rack, heat back through one loop

CDU
SupplyReturn 0design PUE

High-Efficiency Liquid Cooling Piping System

Modular Solution

Modular piping design for rapid deployment and efficient thermal management. Ideal for large-scale data centers and AI training clusters, providing end-to-end liquid cooling solutions from design to maintenance.

Power Systems

Campus Power Architecture: HV → MV → POD

Distribute HV power to independent 10 / 20 MW supply units. Each Power Island has an independent MV feeder, so faults, maintenance or expansion never interrupt its neighbours.

HV Receiving Station

Ownership boundary, revenue metering, protection and bus sectionalization.

HV / MV Main Transformers

Stepped down to the approved MV voltage class.

MV Distribution Zones

Sectionalized buses limit short-circuit and fault impact.

Independent MV Feeders

Dedicated VCB and selective protection per Power Island.

10 / 20 MW Power Island

Independent energization, testing, maintenance and phased expansion.